Aquwell · Automated recalibration

Established calibration
Automated in the field

Aquwell brings known calibration standards to the probe while it stays in the river. A familiar laboratory principle becomes an automatic part of field operation, without a person attending each recalibration.

The trusted principle

A known reference.
A measurement you can check.

Calibration checks a probe against liquids with known values. Laboratories and field teams already use this established method to keep ammonium measurements dependable.

What does calibration actually do?

A calibration standard is a liquid prepared to a known value. For ammonium, it contains a known concentration of ammonium, giving the probe a reference against which its response can be checked.

An ammonium probe uses an ion-selective electrode, or ISE. Its response can change over time. Measuring known standards allows the instrument to check and update the relationship between the signal it receives and the concentration it reports.

The reference comes from a physical solution whose value is already known. FreeUP automates this established practice in the field.

What FreeUP changes

Bring the standards to the probe

The calibration method stays familiar. Aquwell changes who does the recurring work—and where it happens.

Manual calibration

A person retrieves the probe and places it in known reference solutions, at the bank or in a laboratory.

With Aquwell

The reference solutions come to the submerged probe. Recalibration happens automatically, without a person attending each cycle.

How does automatic recalibration fit into operation?

Recalibration can run on a schedule or be started remotely. The instrument carries out the recalibration and then returns to river measurements, without someone travelling to the site to handle the probe and standards.

Used calibration solutions are retained for collection at the bank rather than released into the river. Replenishing supplies forms part of planned servicing.

The strengths of two approaches

In-water measurement.
Laboratory calibration principles.

Keep the sensors in the river, with the known reference standards and automatic care needed to support them.

Together with sensor cleaning, this supports Aquwell’s design around one planned service visit per season.

Measure where the water is

Submerged sensors retain the direct measurement approach of an in-water sonde.

Less sample-transfer equipment

River water does not need to be pumped along a sampling line to a bankside analyser.

Calibrate without retrieval

Routine recalibration requires no probe retrieval or person entering the river.

Why does avoiding a river-to-kiosk sample line matter?

A pumped kiosk brings river water up to instruments on the bank. The length of its sampling tube affects how long water takes to reach the instruments, and its intake, sample line and pumping equipment need to be kept clear and maintained.

Aquwell measures in the river, avoiding that separate sample-transfer circuit and its associated wear and servicing. The calibration standards travel to the probe while the probe stays in place.

At suitable sites, installation, retrieval and planned servicing can also be carried out from the bank.

Considered engineering

Established practice.
Engineered for the field.

FreeUP brings calibration, cleaning and deployment together for unattended river monitoring. Our in-field recalibration technology is patent pending.

The Water Research Centre (WRc) has independently observed FreeUP’s automated ammonium recalibration operating in the field.

What still happens at a planned service visit?

Your team services the station and replenishes calibration supplies. The instrument handles routine recalibration between those visits, reducing repeated travel, site access arrangements and manual calibration work across a network.

Calibration works alongside appropriate sensor selection, cleaning and checks for the water being measured. We help match those elements to your application.

Can other measurements use the same principle?

Known reference solutions are also used to calibrate pH and other compatible ISE measurements. The system is designed to accommodate pH recalibration; WRc’s observation concerns automated ammonium recalibration.

Make routine calibration part of the instrument

Tell us what you need to measure, where the instruments will operate and how you manage site visits. We’ll help define a practical monitoring arrangement.