Is that spike pollution or a sensor problem?
An unexpected water quality spike needs investigation. Learn how timing, neighbouring measurements and instrument checks help test possible explanations.
A sudden spike on a dashboard attracts attention for a good reason. Something may have changed in the river. Something may also have changed in the way the river was measured.
The first useful response is to preserve the evidence and check competing explanations, rather than deciding from the shape of one line.
Check the record around the event
Start with the original timestamps, units and values. Was the sensor being serviced or recalibrated? Did the recording interval change? Was the instrument submerged and operating within its intended conditions?
A flat maximum, an impossible step or a change immediately after maintenance may provide useful clues. None proves an explanation on its own. An isolated reading can be a genuine brief event, and a smooth change can still arise from instrument drift.
Look for independent support
Compare other measurements that describe relevant processes. Rainfall and flow may help explain a turbidity change. Temperature, light and biological activity may help explain an oxygen pattern.
Records from another location can also help, provided differences in travel time and mixing are considered. Agreement between two channels is more useful when there is a plausible reason for them to move together.
A nearby grab sample may add evidence about substances the sensor does not directly measure. Its collection time matters when comparing it with a short event.
Check the instrument without losing the story
Fouling, damaged components and changes in calibration can all affect readings. The USGS continuous monitoring guidance describes the importance of inspection, calibration checks and evaluation of the resulting record.
Keep the original data alongside service notes and any later assessment. If a value is flagged or corrected, record why. Quietly deleting an awkward point can remove evidence that later proves important.
Match the response to the stakes
Checking a measurement does not mean postponing action where there is a credible immediate concern. The response should follow the site’s responsibilities and incident arrangements while the evidence is assessed.
For interpretation, it helps to separate an observed value, a suspected cause and a confirmed explanation. Those are different stages of knowledge.
A good monitoring system helps people move between those stages. It makes the instrument’s condition, the river context and the original record available together, so a decision can be supported by more than the appearance of a spike.